Ideally suited to the needs of Automated Test Equipment and RF requirements. The specification tables allow you to select the appropriate relay for your particular application.  Slightly larger than the 2200 Series;  these relays provide maximum versatility with options such as a Form C with electrostatic or coaxial shielding.  If your requirements differ, please consult your local representative or Coto's Factory.

2900 Series Features
u Very small (0.20 in2), high reliability reed relays.
u High Insulation Resistance - 1012W offered on some models.
u High speed switching compared to electromechanical relays.
u Hermetically sealed contacts for long life.
u Epoxy coated steel shell provides magnetic shielding.
u Optional Electrostatic Shield for reducing capacitive coupling.
u Optional Coaxial Shield for 50 W impedance and switching of fast
    rise time digital pulses.

PDF Logo

2900 Series Mechanicals

2900mech
2900ord

2900 Series Specifications Table

Model  Number

 

 

29042
1 Form A

29112
1 Form C

29202,3
1 Form A
Hg Wet

Parameters

Test Conditions

Units

 

 

 

COIL RESISTANCE

 

 

 

 

 

Nom. Coil Voltage

 

VDC

5          12

5         12

5          12

Coil Resistance

+/- 10%, 25° C

W

370      1500

230      1500

75        250

Operate Voltage

Must Operate by

VDC - Max.

3.8        9.0

3.8        9.0

3.8        9.0

Release Voltage

Must Release by

VDC - Min.

0.4        1.0

0.4        1.0

0.4       1.0

CONTACT RATING

 

 

 

 

 

Switching Voltage

Max DC/Peak AC Resist.

Volts

200

150

500

Switching Current

Max DC/Peak AC Resist.

Amps

0.5

0.25

1.0

Carry Current

Max DC/Peak AC Resist.

Amps

1.5

1.0

2.0

Contact Rating

Max DC/Peak AC Resist.

Watts

10

3

50

Life Expectancy-Typical 1

Signal Level   1.0V, 10mA

x 106 Ops.

500

100

1000

Static Contact
Resistance (max. init.)

50mV, 10mA

W

0.100

0.150

0.075

Dynamic Contact
Resistance (max. init.)

0.5V, 50mA
at 100 Hz, 1.5 msec

W

0.200

0.200

0.100

RELAY SPECIFICATIONS

 

 

 

 

 

Insulation Resistance
(minimum)

Between all Isolated Pins
at 100V, 25°C, 40% RH

W

x 1012

x 1011

x 1010

Capacitance - Typical
Across Open Contacts

Shield Floating
Shield Guarding

pF
pF

1.0
0.3

2.0
1.0

1.4
0.2

Dielectric Strength
(minimum)

Between Contacts
Contacts to Shield
Contacts/Shield to Coil

VDC/peak AC VDC/peak AC VDC/peak AC

350
350
1500

200
200
1500

1000
1000
1500

Operate Time - including
bounce - Typical

At Nominal Coil Voltage,
30 Hz Square Wave

msec.

0.5

1.0

1.5

Release Time - Typical

Zener-Diode Suppression4

msec.

0.1

2.0

1.0

 

 

 

29042
1 Form A

29112
1 Form C

29202,3
1 Form A
Hg Wet

Top View:
Dot stamped on top of relay refers to pin #1 location
Grid = .1"x.1" (2.54mm x 2.54mm)

Get It In .PDF Format

2900s1 2900s2 2900s3

Notes:
1Consult factory for life expectancy at other switching loads.
2Model 2904, 2911 and 2920, pin #7 is tied to optional electrostatic shield, pins #6 & #7 are tied to optional coaxial shield.
3Model 2920 has Hg wet contacts - position sensitive, must be mounted within 30° of vertical plane.  See schematic. Hg Content per capsule: Form A, 0.04 grams.
4Consists of 56V Zener diode and 1N4148 diode in series, connected in parallel with coil.

Environmental Ratings
Storage Temp: -35°C to +100°C
Operating Temp:  -20°C to +85°C
Solder Temp: 270°C max; 10 sec.max
The operate and release voltage and the coil resistance are specified at 25°C. These values vary by approximately 0.4%/°C as the ambient temperature varies.
Vibration:  20 G's to 2000 Hz;  Shock:  50 G's

[Home] [Relays] [Switches] [Sales] [Literature] [Contact Us]

Coto Technology
171 Service Road, Suite 301
Warwick, RI 02886-1015
401-943-2686
FAX: 401-942-0920


 

Coto Logo

Coto Technology BV
Jan Campertstraat 11
6416 SG Heerlen, The Netherlands
+31 45 5439345