Loaded conditions (capacitive load: 80 V; 0.1 mA; (700 mA peak); operating frequency: 100 Hz)
RI-29AA Life expectancy: min. 107 operations with a failure rate of less than 2 x 10-8 with a confidence level of 90%.
End of life criterion: Release time > 2 ms (latching or contact sticking).
RI-29A Life expectancy: min. 2 x 107 operations with a failure rate of less than 10-8 with a confidence level of 90%.
End of life criterion: Release time > 2 ms (latching or contact sticking). Switching different loads involves different life expectancy and reliability data. Further information is available on request.
|