Loaded conditions (resistive load: 5V; 100 mA; operating frequency: 170 Hz)
Life expectancy: min. 107 operations with a failure rate of less than 10-8 with a confidence level of 90%.
End of life criteria: Contact resistance >2W after 4 ms Release time > .7 ms (latching or contact sticking)
Switching different loads involves different life expectancy and reliability data. Further information available upon request.
|