Coto Banner
RI80

RI-80 Series Dry Reed Switch

RI-80 Series

Ultra-micro dry-reed switch hermetically sealed in a gas-filled glass envelope. Single-pole, single-throw (SPST) type, having normally open contacts, and containing two magnetically actuated reeds.
The switch is of the double-ended type and may be actuated by an electromagnet, a permanent magnet or a combination of both.
The device is intended for use in sensors, relays, pulse counters or similar devices.

RI-80 Series Features
u Ideal for ATE switching, proximity sensors & medical applications
u Contact layers: gold, sputtered ruthenium
u Superior glass-to-metal seal and blade alignment

Dimensions in Inches (Millimeters)

RI-80

Model Number

 

 

RI-80

Parameters

Test Conditions

Units

 

 

 

 

 

Operating Characteristics

 

 

 

Operate Range

 

AT

5-15

Release Range

 

AT

2-13

Operate Time - including bounce (typ.)

 

ms

 0.35 (20 AT)

Bounce Time (typ.)

 

ms

0.1 (20 AT)

Release Time (max)

 

µs

 20 (20 AT)

Resonant Frequency (typ.)

 

Hz

21300

 

 

 

 

Electrical Characteristics

 

 

 

Switched Power (max)

 

W

5

Switched Voltage DC (max)

 

V

175*

Switched Voltage AC, RMS value (max)

 

V

140

Switched Current DC (max)

 

mA

350

Switched Current AC, RMS value (max)

 

mA

250

Carry Current DC; AC, RMS value (max)

 

A

0.5

Breakdown Voltage (min)

 

V

230

Contact Resistance (initial max)

(energization)

m W

160 (20 AT)

Contact Resistance (initial typ.)

(energization)

m W

140 (20 AT)

Contact Capacitance (max)

without test coil

pF

0.45

Insulation Resistance (min)

RH £ 45%

M W

106

* 200V for switches with AT on value > 10AT

General data for all models RI-80

AT-Customization / Preformed Leads
 Besides the standard models, customized products can also be supplied offering the following options:
Operate and release ranges to customer specification
Cropped and/or preformed leads

Coils
All characteristics are measured using the Philips Standard Coil. For definitions of the Philips Standard Coil, see Reed Technical & Application Information Section of this catalog.

Life expectancy and reliability
The life expectancy data given below are valid for a coil energized at 1.25 times the published maximum operate value for each type in the RI-80 series.

No-load conditions (operating frequency: 100 Hz)

Life expectancy: min. 108 operations with a failure rate of less than 2 x 10-9 with a confidence level of 90%.

End of life criteria:
   Contact resistance >1W after 2 ms
   Release time > 2 ms (latching or contact sticking)

Loaded conditions (resistive load: 5V; 100 mA; operating frequency: 170 Hz)

 Life expectancy: min. 107 operations with a failure rate of less than 10-8 with a confidence level of 90%.

End of life criteria:
   Contact resistance >2W after 4 ms
   Release time > .7 ms (latching or contact sticking)

Switching different loads involves different life expectancy and reliability data. Further information available upon request.

Mechanical Data
Contact arrangement is normally open; lead finish is tinned; net mass is approximately 65mg; and can be mounted in any position.

Shock
The switches are tested in accordance with "IEC 68-2-27", test Ea (peak acceleration 150 G, half sinewave; duration 11 ms). Such a shock will not cause an open switch (no magnetic field present) to close, nor a switch kept closed by an 80 AT coil to open.

Vibration
The switches are tested in accordance with "IEC 68-2-6", test Fc (acceleration 10 G; below cross-over frequency 57 to 62 Hz; amplitude 0.75 mm; frequency range 10 to 2000 Hz, duration 90 minutes). Such a vibration will not cause an open switch (no magnetic field present) to close, nor a switch kept closed by an 80 AT coil to open.

Mechanical Strength
The robustness of the terminations is tested in accordance with "IEC 68-2-21", test Ua1 (load 10 N).

Operating and Storage Temperature
 Operating ambient temperature; min: -55°C; max: +125°C.
Storage temperature; min: -55°C; max: +125°C.
Note: Temperature excursions up to 150°C may be permissible. For more information contact your nearest Coto Technology sales office.

Soldering
The switch can withstand soldering heat in accordance with "IEC 68-2-20", test Tb, method 1B: solder bath at 350 ±10°C for 3.5 ±0.5 s. Solderability is tested in accordance with "IEC 68-2-20", test Ta, method 3: solder globule temperature 235°C; ageing 1b: 4 hours steam.

Welding
The leads can be welded.

Mounting
The leads should not be bent closer than 1 mm to the glass-to-metal seals. Stress on the seals should be avoided. Care must be taken to prevent stray magnetic fields from influencing the operating and measuring conditions.

Get It In .PDF Format

PDF Logo
[Home] [Relays] [Switches] [Sales] [Literature] [Contact Us]

Coto Technology
171 Service Road, Suite 301
Warwick, RI 02886-1015
401-943-2686
FAX: 401-942-0920


 

Coto Logo

Coto Technology BV
Jan Campertstraat 11
6416 SG Heerlen, The Netherlands
+31 45 5439345